Alpha Prime Context

Specifications

  • Max Range M: 300 m (at 10% NIST reflectivity; configuration-dependent)
  • LIDAR Channels: 128 channels
  • Horizontal Fov Deg: 360 deg
  • Range: 180 m at 5% NIST reflectivity
  • Range Accuracy Cm: ±3 cm typical
  • Points Per Second: ≤2.3 million single-return; ≤4.6 million dual-return
  • Frame Rate: 5–20 Hz; characterized at 10 Hz
  • Power Consumption W: 23 W typical
  • Weight: 3.5 kg (without cabling)
  • Ingress Protection: IP67
  • Laser Wavelength Nm: ≈905 nm
  • Operating Temperature C: −20 to +60 °C under typical conditions
  • Interfaces: 1000BASE-T Ethernet; UDP point cloud
  • Vertical Fov Deg: 40° (−25° to +15°)

Comparable Systems