FIPA cuts sorting-system air consumption at JELD-WEN

Apr 13, 2026 · Deployment · FIPA · End Effectors

FIPA modernized a JELD-WEN package-sorting system with a centralized FMC multi-chamber ejector.

FIPA company media
Company media · FIPA
  • FIPA replaced twelve individual ejectors with one FMC multi-chamber ejector on a JELD-WEN door-packaging line.
  • Measured compressed-air demand fell from 540 litres per minute to 220 litres per minute, a reduction of about 60 percent.
  • The retrofit also reduced noise and gripping faults while improving availability of the twenty-year-old sorting system.